Tissue state of anterior abdominal wall in rats after implantation of alloplastic material, processed with collagen, in the abdominal cavity and in contact with hollow organs.
DOI:
https://doi.org/10.26641/1997-9665.2010.4.13-18Keywords:
polypropylene mesh, collagen, transabdominal fixation, tissue reactionAbstract
A research purpose was to investigate the tissue reactions on implantation of polypropylene mesh, processed with collagen, after the plastic of experimental defect at rats at intraperitoneal localization of prosthesis in contact with hollow organs. Research was performed in two experimental groups. Group 1 – at 27 rats an experimental defect of of anterior abdominal wall of size 3 cm, with further transabdominal fixation of the polypropylene mesh of size 1×1,5 cm on parietal peritoneum in contact with hollow organs, was performed. Group 2 – at 28 rats at analogous conditions the intraperitoneal fixation of polypropylene mesh, processed with collagen, was performed. Morphological analysis of scar tissue formation phases in rats in the implantation region in the abdominal cavity and contact with hollow organs from the data of cellular and fiber structures stereological characteristics of connective tissue with hemodynamic characteristics shows substantial benefits of use of polypropylene mesh, processed with collagen, during 4 weeks after experimental hernioplasty.
References
- Автандилов Г. Г. Системная стереометрия в изучении патологического процесса / Г. Г. Автандилов, Н. И. Яблучанский, В. Г. Губенко. – М. : Медицина, 1981. – 192 с.
- Ромейс Б. Микроскопическая техника: [Пер. с нем] / Б. Ромейс. – М. : Изд-во иностр. литературы, 1953. – 718 с.
- Твердохлеб И. В. Прикладная биометрия для морфолога / И. В. Твердохлеб, И. С. Шпонька, М. А. Машталир. – Днепропетровск : Пороги, 1996. – 226 с.
- Шалимов С. А. Руководство по экспериментальной хирургии / С. А. Шалимов, А. П. Радзиховский, Л. В. Кейсевич. - М. : Медицина, 1989. - 272 с.
- Экспериментальное обоснование применения новых поливинилиденфторидных эндопротезов с карбиновым покрытием для герниопластики / А. И. Бежин, А. А. Должиков, В. А. Жуковский, Р. В. Плотников // Вестн. новых медицинских технологий. – 2007. - Т. XIV, № 1. – С. 99–101.
- Antibacterial activity of triclosan chitosan coated graft on hernia graft infection model / A. Cakmak, Y Cirpanli, E. Bilensoy [et al.] // Int. J. Pharm. – 2009. – Vol. 381, № 2. – P. 214-219.
- Brown C. N. Which mesh for hernia repair? / C. N. Brown, J. G. Finch // Ann. R. Coll. Surg. Engl. – 2010. – Vol. 92, № 4. – P. 272-278.
- Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs / D. Akolekar, S. Kumar, L. R. Khan [et al.] // Hernia. – 2008. –Vol. 12, № 1. – P. 39-43.
- Eriksen J. R. Choice of mesh for laparoscopic ventral hernia repair / J. R. Eriksen, I. Gögenur, J. Rosenberg // Hernia. – 2007. – Vol. 11, № 6. – P. 481-492.
- Evaluation of lightweight titanium-coated polypropylene mesh (TiMesh) for laparoscopic repair of large hiatal hernias // E. J. Hazebroek, A. Ng, D. H. Yong [et al.] // Surg Endosc. – 2008. – Vol. 22, № 11. – P. 2428-2432.
- Saberski E. R. Anisotropic evaluation of synthetic surgical meshes // E. R Saberski, S. B. Orenstein, Y. W. Novitsky // Hernia. – 2010. – Vol. 30. – P. 423-431.
- Use of human acellular dermal matrix for hernia repair: friend or foe? / R. Candage, K. Jones, F. A. Luchette [et al.] // Surgery. – 2008. – Vol. 144, № 4. – P. 703-709.
Downloads
How to Cite
Issue
Section
License
Copyright (c) 2019 Morphologia

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors reserve the right to authorship of their work and transfer to the Journal the right to the first publication of this work under the terms of a license Creative commons Attribution 4.0 International (CC BY 4.0), which allows other people to freely distribute the published work with a mandatory reference to the authors of the original work and the first publication of the work in this journal.By submitting a manuscript to the editorial office of the Journal ‘Morphologia’ authors agree to transfer the rights to protect and use the manuscript (all supplemental materials, particularly protected objects such as photos, drawings, diagrams, tables, etc.), including the reproduction in the press and distribution via the Internet; translation of the manuscript into any language; export and import of journal copies with the Authors’ article in order to make it available for public. Authors convey the rights mentioned above to the editorial office without any temporal or territorial limitation all over the world.
The Authors guarantee that they have the exclusive rights to use the material transferred to editorial office. Editors are not responsible to third parties for contraventions of warranty given by the Authors. The considered rights are transferred to the editorial office since the moment when the current issue is signed for publishing. Reproduction of materials published in the Journal by other individuals and legal entities is possible only with the consent of Editorial office, with the obligatory indication of the full bibliographic reference of the primary publication. The Authors reserve the right to use the published material, its fragments and parts for teaching materials, oral presentations, dissertation thesis prepararion with obligatory bibliographic citation of the original paper. Electron copy of the published article, downloaded from official journal web-site in .pdf format may be put by authors on the official web-site of their institutions, any other official resources with open access.